CEI Cheat Sheet 2026
The 30 highest-yield CEI facts, distilled from real exam questions. Print it, save it as a PDF, or study it here — free, no sign-up.
100 questions
120 min time limit
75% to pass
- The National Electrical Safety Code (NESC) primarily applies to which type of electrical installation? → Utility supply lines and communication systems
- Which of the following best describes a key competency required for commercial & industrial systems in CEI practice? → Strong analytical skills combined with effective communication and ethical judgment
- An AEx marking on equipment indicates it has been certified under which standard? → ATEX European directive
- An inspector finds recessed lighting fixtures in direct contact with attic insulation. The fixtures are marked 'IC'. What does this marking indicate? → The fixture is rated for insulation contact and can be covered by insulation
- During inspection, a motor nameplate indicates 'SF 1.15.' What does this service factor mean? → The motor is rated for continuous duty at 115% of its nameplate horsepower
- Which NEC section addresses the requirement that service-entrance conductors must be protected against physical damage? → NEC 230.50
- A commercial wind energy system uses a guy-wire supported tower. What grounding requirement applies to the guy wires under NEC 694.40? → Metallic guy wires must be bonded to the tower's grounding electrode system
- Which type of bushing is required when rigid metal conduit enters a cabinet or enclosure without a threaded hub? → Insulating bushing or insulated fitting
- Which device automatically disconnects power when arc-fault conditions are detected? → AFCI breaker
- When a generator serves both emergency and legally required standby loads, the two systems must: → Have separate transfer switches unless the generator has sufficient capacity
- What does NEC 600.6 require for signs and outline lighting in commercial buildings regarding disconnecting means? → An externally operable switch or circuit breaker within sight of the sign
- Which inspection method is most appropriate for verifying conductor insulation integrity in an existing installation? → Megohmmeter (insulation resistance) testing
- Under NEC 701.12, legally required standby power must be available within how many seconds of normal power failure? → 60 seconds
- In a commercial building, what is the minimum burial depth for rigid metal conduit (RMC) installed under a parking lot? → 12 in
- Which authority is responsible for classifying which loads belong on an emergency system versus a legally required standby system? → The authority having jurisdiction (AHJ)
- What is the maximum voltage permitted for a PV system installed on a one- or two-family dwelling under NEC 690.7? → 600V
- What is the maximum distance a receptacle outlet can be placed from a doorway along a wall space in a residential living room per NEC 210.52(A)? → 6 feet
- Which NEC section requires ground-fault circuit-interrupter (GFCI) protection for 125V, 15A and 20A receptacles in commercial bathrooms? → 210.8(B)
- When inspecting a CT (current transformer) metering installation, why are instrument transformers used? → To reduce high current to a manageable level for meter measurement
- Under NEC 700.10, emergency system wiring must be kept entirely independent of other wiring EXCEPT when: → Both circuits are in separate raceways within the same enclosure
- Which safety gear is essential during inspections? → Gloves and safety glasses
- Which of the following best describes a key competency required for renewable energy system inspection in CEI practice? → Strong analytical skills combined with effective communication and ethical judgment
- What is the maximum distance allowed between a motor disconnect and the motor controller, according to NEC 430.102? → Within sight from the controller
- A separately derived system's grounding electrode conductor must be connected at which point? → At the source of the separately derived system
- Per NEC 215.2(A)(1), feeder conductor ampacity must be not less than which of the following? → 100% of non-continuous load plus 125% of continuous load
- When inspecting a commercial kitchen, which NEC section would a CEI reference to verify GFCI protection requirements for receptacles? → 210.8(B)
- Under NEC 230.79, what is the minimum ampere rating required for the service disconnecting means of a single-family dwelling? → 100 amperes
- Bonding of metal gas piping is required when the piping system could become energized. The bond must be connected to: → The equipment grounding conductor or grounded service conductor
- Which statement best describes a 'separate service' as an emergency source under NEC 700.12(D)? → A service from a separate utility or network protector on a different utility grid section
- Which Group classification applies to acetylene in hazardous location wiring? → Group A
Turn these facts into recall:
What Practice Test Geeks adds beyond an AI chat for CEI
An AI chatbot can quiz you, but it can't reproduce the exam conditions or keep your record. Here you get:
- A timed, full-length CEI mock exam — 100 questions in 120 minutes with a 75% pass mark, modeled on the official exam's question count and time limit, followed by a score report broken down by exam domain.
- A fixed CEI question bank: the same test every attempt, so your score is comparable from one try to the next instead of changing with every regenerated quiz.
- Progress saved on your device: completed tests, scores and missed questions stay in My Progress, so you can retake only what you got wrong.
- CEI flashcards built from the same question bank.
- Free CEI practice tests with the correct answer shown after each question.
Was this helpful?