Mixed Deck — All CBI Topics Flashcards
100 cards from real CBI practice questions. Tap to flip, then mark Knew It or Still Learning — missed cards come back until you master them.
Read the first 20 Mixed Deck — All CBI Topics flashcards as text
How often should a fuel-burning furnace or boiler typically be professionally serviced?
Answer: Annually
Annual professional service checks combustion, venting, heat exchangers, and safety controls.
Fireblocking in concealed spaces of stud walls is required at what maximum horizontal interval?
Answer: 10 feet
IRC R302.11 requires fireblocking so that horizontal concealed spaces do not exceed 10 feet.
An IRC stairway requires a handrail on at least one side when it has how many or more risers?
Answer: Four
IRC R311.7.8 requires a handrail on at least one side of each flight with four or more risers.
Impervious surfaces such as driveways and patios within 10 feet of a building should slope away at a minimum of what percentage?
Answer: 2%
IRC R401.3 requires impervious surfaces within 10 feet of the foundation to slope at least 2% away.
Anchor bolts must be located within what distance of each end of a sill plate section?
Answer: 12 inches
The IRC requires an anchor bolt within 12 inches of each end of each plate section.
Why can a frost-free sillcock still freeze and burst in winter?
Answer: A garden hose left attached traps water in the valve body
An attached hose keeps water from draining out of the barrel, so it can freeze; hoses should be disconnected before winter.
An inspector sees a stair-step crack running diagonally through the mortar joints of a concrete block foundation wall. What is the most likely cause?
Answer: Differential settlement
Stair-step cracks along mortar joints usually mean one part of the foundation has settled more than another.
During a winter inspection, the outdoor unit of a heat pump briefly stops its fan and releases steam. What is the most likely explanation?
Answer: Normal defrost cycle
Heat pumps periodically enter defrost mode, melting frost off the outdoor coil and producing visible steam.
An inspector runs several fixtures at once and sees a big drop in flow. This test checks:
Answer: Functional water flow and possible restriction in the supply
A noticeable flow drop with multiple fixtures open suggests undersized or restricted supply piping, such as corroded galvanized pipe.
Which procedure ensures machinery or electrical circuits stay de-energized while being worked on or examined?
Answer: Lockout/tagout
Lockout/tagout under OSHA 1910.147 isolates energy sources and prevents accidental re-energizing.
Under the IRC, handrail height measured vertically from the sloped plane of the tread nosings must fall within what range?
Answer: 34 to 38 inches
IRC R311.7.8.1 requires handrails to be between 34 and 38 inches above the tread nosings.
Within a single stair flight, the greatest riser height may not exceed the smallest by more than what amount?
Answer: 3/8 inch
The IRC limits variation between the largest and smallest riser or tread in a flight to 3/8 inch.
Which organization publishes the International Building Code (IBC)?
Answer: International Code Council
The International Building Code (IBC) is a comprehensive model building code adopted across the United States and internationally. It is developed and published by the International Code Council (ICC), a non-profit organization. The ICC's mission is to provide a single set of coordinated codes for the construction industry, promoting safety and consistency.
During a standard home inspection, the inspector should generally NOT operate the water heater's:
Answer: Temperature and pressure relief (TPR) valve
A TPR valve that has not been opened in a long time may not reseat and can leak, so the SOP does not require testing it.
What environmental protection measure applies to environmental standards?
Answer: Proper handling, storage, and disposal of materials according to environmental regulations
Proper handling, storage, and disposal of all materials according to environmental regulations is a legal obligation in all trades.
In a crawlspace, a wood post sits directly on bare soil with no footing. What is the inspector's main concern?
Answer: Decay, insect attack, and settlement of an unsupported post
Wood in direct soil contact rots and attracts termites, and without a footing the post can sink.
What code compliance requirement applies to maintenance protocols?
Answer: All work must comply with applicable local, state, and national codes
Code compliance is mandatory for all work, ensuring safety, quality, and legal adherence.
What is the primary purpose of a concrete slump test performed on site?
Answer: To measure workability and consistency of fresh concrete
The slump test (ASTM C143) measures the consistency and workability of fresh concrete.
What is the typical acceptable temperature drop across a working evaporator coil in cooling mode?
Answer: 14–22°F
A supply-to-return drop of about 14–22°F generally means the cooling system is working normally.
Under a standard home inspection SOP, an inspector is NOT required to:
Answer: Light pilot lights that are out
Inspectors may operate systems with normal controls but are not required to light pilot lights.