What is the minimum ceiling height required for habitable spaces under the IRC?
Answer: 7 feet
IRC R305.1 requires a minimum ceiling height of 7 feet in habitable spaces.
Under the IRC, habitable rooms (other than kitchens) must have a floor area of at least how many square feet?
Answer: 70 sq ft
IRC R304.1 requires at least 70 square feet with no horizontal dimension under 7 feet.
Unless on solid rock or frost-protected, IRC footings must extend at least how far below undisturbed ground surface?
Answer: 12 inches
IRC R403.1.4 requires footings at least 12 inches below undisturbed ground.
Anchor bolts securing a wood sill plate to a foundation under the IRC must be spaced no more than how far apart?
Answer: 6 feet on center
IRC R403.1.6 requires 1/2-inch anchor bolts at a maximum of 6 feet on center.
In a crawl space, untreated wood joists must be at least how far from exposed ground to avoid requiring decay-resistant or treated lumber?
Answer: 18 inches
IRC R317.1 requires naturally durable or treated wood where joists are closer than 18 inches to exposed ground.
Crawl space ventilation openings under the IRC must provide a net area of at least 1 square foot for every how many square feet of crawl space area?
Answer: 150 sq ft
IRC R408.1 requires 1 sq ft of net vent area per 150 sq ft, reducible to 1/1,500 with a vapor retarder.
Under the IRC, notches in exterior or bearing wall studs may not exceed what percentage of the stud width?
Answer: 25 percent
IRC R602.6 limits notches in bearing studs to 25 percent of their width.